<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "http://dtd.nlm.nih.gov/publishing/2.0/journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="2.0">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">JMBE</journal-id>
      <journal-id journal-id-type="nlm-ta">JMIR Biomed Eng</journal-id>
      <journal-title>JMIR Biomedical Engineering</journal-title>
      <issn pub-type="epub">2561-3278</issn>
      <publisher>
        <publisher-name>JMIR Publications</publisher-name>
        <publisher-loc>Toronto, Canada</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
    <article-id pub-id-type="publisher-id">v3i1e1</article-id>
    <article-id pub-id-type="pmid"/>
    <article-id pub-id-type="doi">10.2196/biomedeng.9062</article-id>
    <article-categories>
      <subj-group subj-group-type="heading">
        <subject>Original Paper</subject>
      </subj-group>
      <subj-group subj-group-type="article-type">
        <subject>Original Paper</subject>
      </subj-group>
    </article-categories>
    <title-group>
      <article-title>Wireless Surface Electromyography and Skin Temperature Sensors for Biofeedback Treatment of Headache: Validation Study with Stationary Control Equipment</article-title>
    </title-group>
    <contrib-group>
      <contrib contrib-type="editor">
        <name>
          <surname>Eysenbach</surname>
          <given-names>Gunther</given-names>
        </name>
      </contrib>
    </contrib-group>
    <contrib-group>
      <contrib contrib-type="reviewer">
        <name>
          <surname>Minen</surname>
          <given-names>Mia</given-names>
        </name>
      </contrib>
      <contrib contrib-type="reviewer">
        <name>
          <surname>Arai</surname>
          <given-names>Young-Chang P</given-names>
        </name>
      </contrib>
    </contrib-group>
    <contrib-group>
      <contrib contrib-type="author" id="contrib1" corresp="yes">
      <name name-style="western">
        <surname>Stubberud</surname>
        <given-names>Anker</given-names>
      </name>
      <xref rid="aff1" ref-type="aff">1</xref>
      <address>
        <institution>Department of Neuromedicine and Movement Science</institution>
        <institution>Norwegian University of Science and Technology</institution>
        <addr-line>Nevro Øst, Edvard Griegs Gate 8</addr-line>
        <addr-line>Trondheim, 7030</addr-line>
        <country>Norway</country>
        <phone>47 73 59 20 20</phone>
        <email>ankers@stud.ntnu.no</email>
      </address>  
      <ext-link ext-link-type="orcid">http://orcid.org/0000-0003-0934-9914</ext-link></contrib>
      <contrib contrib-type="author" id="contrib2">
        <name name-style="western">
          <surname>Omland</surname>
          <given-names>Petter Moe</given-names>
        </name>
        <degrees>PhD</degrees>
        <xref rid="aff1" ref-type="aff">1</xref>
        <xref rid="aff2" ref-type="aff">2</xref>
        <ext-link ext-link-type="orcid">http://orcid.org/0000-0002-1160-6230</ext-link>
      </contrib>
      <contrib contrib-type="author" id="contrib3">
        <name name-style="western">
          <surname>Tronvik</surname>
          <given-names>Erling</given-names>
        </name>
        <degrees>PhD</degrees>
        <xref rid="aff1" ref-type="aff">1</xref>
        <xref rid="aff3" ref-type="aff">3</xref>
        <ext-link ext-link-type="orcid">http://orcid.org/0000-0001-6059-0151</ext-link>
      </contrib>
      <contrib contrib-type="author" id="contrib4">
        <name name-style="western">
          <surname>Olsen</surname>
          <given-names>Alexander</given-names>
        </name>
        <degrees>PhD</degrees>
        <xref rid="aff4" ref-type="aff">4</xref>
        <xref rid="aff5" ref-type="aff">5</xref>
        <ext-link ext-link-type="orcid">http://orcid.org/0000-0001-8691-3860</ext-link>
      </contrib>
      <contrib contrib-type="author" id="contrib5">
        <name name-style="western">
          <surname>Sand</surname>
          <given-names>Trond</given-names>
        </name>
        <degrees>PhD</degrees>
        <xref rid="aff1" ref-type="aff">1</xref>
        <xref rid="aff3" ref-type="aff">3</xref>
        <ext-link ext-link-type="orcid">http://orcid.org/0000-0002-9755-8187</ext-link>
      </contrib>
      <contrib contrib-type="author" id="contrib6">
        <name name-style="western">
          <surname>Linde</surname>
          <given-names>Mattias</given-names>
        </name>
        <degrees>PhD</degrees>
        <xref rid="aff1" ref-type="aff">1</xref>
        <xref rid="aff3" ref-type="aff">3</xref>
        <ext-link ext-link-type="orcid">http://orcid.org/0000-0002-6026-3596</ext-link>
      </contrib>
    </contrib-group>
    <aff id="aff1">
    <sup>1</sup>
    <institution>Department of Neuromedicine and Movement Science</institution>
    <institution>Norwegian University of Science and Technology</institution>  
    <addr-line>Trondheim</addr-line>
    <country>Norway</country></aff>
    <aff id="aff2">
    <sup>2</sup>
    <institution>Department of Neurology and Clinical Neurophysiology</institution>
    <institution>St Olavs Hospital</institution>  
    <addr-line>Trondheim</addr-line>
    <country>Norway</country></aff>
    <aff id="aff3">
    <sup>3</sup>
    <institution>National Advisory Unit on Headaches</institution>
    <institution>Section of Neurology</institution>  
    <institution>St Olavs Hospital</institution>  
    <addr-line>Trondheim</addr-line>
    <country>Norway</country></aff>
    <aff id="aff4">
    <sup>4</sup>
    <institution>Department of Psychology</institution>
    <institution>Norwegian University of Science and Technology</institution>  
    <addr-line>Trondheim</addr-line>
    <country>Norway</country></aff>
    <aff id="aff5">
    <sup>5</sup>
    <institution>Department of Physical Medicine and Rehabilitation</institution>
    <institution>St Olavs Hospital</institution>  
    <addr-line>Trondheim</addr-line>
    <country>Norway</country></aff>
    <author-notes>
      <corresp>Corresponding Author: Anker Stubberud 
      <email>ankers@stud.ntnu.no</email></corresp>
    </author-notes>
    <pub-date pub-type="collection"><season>Jan-Dec</season><year>2018</year></pub-date>
    <pub-date pub-type="epub">
      <day>23</day>
      <month>02</month>
      <year>2018</year>
    </pub-date>
    <volume>3</volume>
    <issue>1</issue>
    <elocation-id>e1</elocation-id>
    <!--history from ojs - api-xml-->
    <history>
      <date date-type="received">
        <day>28</day>
        <month>9</month>
        <year>2017</year>
      </date>
      <date date-type="rev-request">
        <day>9</day>
        <month>12</month>
        <year>2017</year>
      </date>
      <date date-type="rev-recd">
        <day>21</day>
        <month>1</month>
        <year>2018</year>
      </date>
      <date date-type="accepted">
        <day>23</day>
        <month>1</month>
        <year>2018</year>
      </date>
    </history>
    <!--(c) the authors - correct author names and publication date here if necessary. Date in form ', dd.mm.yyyy' after jmir.org-->
    <copyright-statement>©Anker Stubberud, Petter Moe Omland, Erling Tronvik, Alexander Olsen, Trond Sand, Mattias Linde. Originally published in JMIR Biomedical Engineering (http://biomedeng.jmir.org), 23.02.2018.</copyright-statement>
    <copyright-year>2018</copyright-year>
    <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
      <p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Biomedical Engineering, is properly cited. The complete bibliographic information, a link to the original publication on http://biomedeng.jmir.org/, as well as this copyright and license information must be included.</p>
    </license>  
    <self-uri xlink:href="http://biomedeng.jmir.org/2018/1/e1/" xlink:type="simple"/>
    <abstract>
      <sec sec-type="background">
        <title>Background</title>
        <p>The use of wearables and mobile phone apps in medicine is gaining attention. Biofeedback has the potential to exploit the recent advances in mobile health (mHealth) for the treatment of headaches.</p>
      </sec>
      <sec sec-type="objectives">
        <title>Objectives</title>
        <p>The aim of this study was to assess the validity of selected wireless wearable health monitoring sensors (WHMS) for measuring surface electromyography (SEMG) and peripheral skin temperature in combination with a mobile phone app. This proof of concept will form the basis for developing innovative mHealth delivery of biofeedback treatment among young persons with primary headache.</p>
      </sec>
      <sec sec-type="methods">
        <title>Methods</title>
        <p>Sensors fulfilling the following predefined criteria were identified: wireless, small size, low weight, low cost, and simple to use. These sensors were connected to an app and used by 20 healthy volunteers. Validity was assessed through the agreement with simultaneous control measurements made with stationary neurophysiological equipment. The main variables were (1) trapezius muscle tension during different degrees of voluntary contraction and (2) voluntary increase in finger temperature. Data were statistically analyzed using Bland-Altman plots, intraclass correlation coefficient (ICC), and concordance correlation coefficient (CCC).</p>
      </sec>
      <sec sec-type="results">
        <title>Results</title>
        <p>The app was programmed to receive data from the wireless sensors, process them, and feed them back to the user through a simple interface. Excellent agreement was found for the temperature sensor regarding increase in temperature (CCC .90; 95% CI 0.83-0.97). Excellent to fair agreement was found for the SEMG sensor. The ICC for the average of 3 repetitions during 4 different target levels ranged from .58 to .81. The wireless sensor showed consistency in muscle tension change during moderate muscle activity. Electrocardiography artifacts were avoided through right-sided use of the SEMG sensors. Participants evaluated the setup as usable and tolerable.</p>
      </sec>
      <sec sec-type="conclusions">
        <title>Conclusions</title>
        <p>This study confirmed the validity of wireless WHMS connected to a mobile phone for monitoring neurophysiological parameters of relevance for biofeedback therapy.</p>
      </sec>
    </abstract>
    <kwd-group>
      <kwd>biofeedback</kwd>
      <kwd>mobile phone</kwd>
      <kwd>app</kwd>
      <kwd>migraine</kwd>
      <kwd>pediatric</kwd>
    </kwd-group></article-meta>
  </front>
  <body>
    <sec sec-type="introduction">
      <title>Introduction</title>
      <p>In the emerging era of mobile health (mHealth) and technology, the use of wearable sensors and mobile phone health apps has recently gained attention. This has led to a subcategory of health informatics, labeled mHealth, encompassing the use of mobile phones for medical purposes [<xref ref-type="bibr" rid="ref1">1</xref>]. In addition to these apps, there is also a wide array of wearable health monitoring sensors (WHMS) [<xref ref-type="bibr" rid="ref2">2</xref>],which represent a means for patients to access real-time data from a broad range of physiological parameters at home [<xref ref-type="bibr" rid="ref3">3</xref>-<xref ref-type="bibr" rid="ref5">5</xref>], thus enabling extensive data acquisition [<xref ref-type="bibr" rid="ref6">6</xref>]. mHealth is of special interest to the younger generation, which is constantly exposed to and familiarized with such technology. It is also increasing in popularity within the field of headache care and research. In particular, mobile phone–based headache diaries are frequently used [<xref ref-type="bibr" rid="ref7">7</xref>]. However, there is a potential for extending this mobile technology into the preventive treatment of headache disorders, such as migraine. The bulk of current mHealth research focuses on chronic conditions and delivery of self-educational treatment [<xref ref-type="bibr" rid="ref8">8</xref>], fitting the description of behavioral headache treatments. Biofeedback, one of the several behavioral headache treatments, is well established and empirically supported [<xref ref-type="bibr" rid="ref9">9</xref>]. Systematic reviews with meta-analyses demonstrated that biofeedback is effective as a migraine prophylaxis in both the adult and pediatric populations [<xref ref-type="bibr" rid="ref10">10</xref>,<xref ref-type="bibr" rid="ref11">11</xref>]. However, the treatment is both time-consuming and costly and therefore not readily available for those in need. Thus, a more optimal approach for behavioral headache treatment has long been sought [<xref ref-type="bibr" rid="ref12">12</xref>,<xref ref-type="bibr" rid="ref13">13</xref>]. Biofeedback has the potential to exploit the recent advances in mHealth technology [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref15">15</xref>]. All the while, biofeedback mHealth solutions for other purposes, such as exercise and postcancer swallowing exercises, are being developed [<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref17">17</xref>].</p>
      <p>Modalities proven effective in biofeedback treatment for headache disorders include surface electromyography (SEMG) and peripheral skin temperature. Both modalities are common in the current development of WHMS [<xref ref-type="bibr" rid="ref2">2</xref>] and may serve as natural elements in the implementation of biofeedback solutions. Nevertheless, such WHMS sensors have not been validated for use in neurophysiological monitoring for the purpose of biofeedback therapy.</p>
      <p>The aim of this study was to assess the validity of WHMS for measuring SEMG and peripheral skin temperature in combination with a mobile phone app. This proof of concept would form the basis for the development of a novel, innovative mHealth system for biofeedback therapy for young persons with primary headache.</p>
    </sec>
    <sec sec-type="methods">
      <title>Methods</title>
      <sec>
        <title>Study Design</title>
        <p>In the first phase of the study, we identified suitable WHMS and developed the preliminary software. In the second phase of the study, we recruited healthy volunteers to establish the validity of the chosen WHMS. The study was exploratory in nature, with the main aim to evaluate the validity of the chosen WHMS by assessing the agreement compared with stationary neurophysiological equipment following recommended guidelines for agreement studies [<xref ref-type="bibr" rid="ref18">18</xref>].</p>
      </sec>
      <sec>
        <title>Identification of Sensors</title>
        <p>The inclusion criteria and requirements for suitable sensors were (1) wireless setup, (2) small size, (3) low weight, (4) simple to use compared with standard clinical equipment, and (5) low cost.</p>
      </sec>
      <sec>
        <title>Software Development</title>
        <p>The first version of the app was created as a minimal viable product (MVP). This preliminary version was programmed to serve as the starting point of iterative and incremental rounds of testing [<xref ref-type="bibr" rid="ref19">19</xref>], allowing subsequent development and fine-tuning of the user interface and software components in an upcoming usability study.</p>
      </sec>
      <sec>
        <title>Participants</title>
        <p>We considered a sample size of 18 to be sufficient, based on the model for sample size determination in reliability studies presented by Bonett [<xref ref-type="bibr" rid="ref20">20</xref>] (<xref ref-type="app" rid="app1">Multimedia Appendix 1</xref>). We set out to recruit 20 healthy volunteers to account for potential dropouts. Participants were recruited as a convenience sample by actively seeking out young individuals from the local research and student community. Exclusion criteria were reduced hearing, vision, or sensibility, and severe neurologic or psychiatric disease.</p>
      </sec>
      <sec>
        <title>Equipment</title>
        <p>TheNeckSensor (EXPAIN, Oslo, Norway) was selected as the wireless WHMS to measure muscle tension. This is a small, compact bipolar SEMG sensor, with a single SR-R adhesive gel patch containing both electrodes (total patch area, 19.8 cm<sup>2</sup>), and no patient ground electrode. For wireless measurement of temperature, we selected the PASPORT Skin/Surface Temperature Probe, PS-2131, combined with PASPORT Temperature sensor, PS-2125, and AirLink, PS-3200 (Pasco, Roseville, CA, USA). Both the sensors transmitted signals via Bluetooth Smart/4.0.</p>
        <p>As the stationary equipment, the following AD Instruments (Dunedin, New Zealand) setup was used: (1) SMEG signals recorded with 5-Lead Shielded Lead Wires (MLA2505) and 5-Lead Shielded BioAmp cable (MLA2540) attached to Red Dot 2560 electrodes with a silver/silver-chloride 3.48 cm<sup>2</sup> sensor area (3M Health Care, Germany) fed through a Dual BioAmp, FE135, and PowerLab 8/35; (2) equivalent lead wires, cables, and electrodes for registration of an electrocardiogram (ECG) through a separate Dual BioAmp; and (3) temperature registered through Skin Temperature Pod and Probe, ML309 + MLT422/A fed through PowerLab. The recordings were visualized and analyzed using the LabChart 8 software (AD Instruments, Dunedin New Zealand) installed on a Dell Latitude E4310 laptop.</p>
      </sec>
      <sec>
        <title>Experimental Procedure</title>
        <p>Participants were seated in a recliner at a 90 degree angle in the neurophysiological laboratory. The 2 electrodes from the NeckSensor were placed over the upper fibers of the right trapezius muscle midway along the line between the spinous process C7 and the acromion [<xref ref-type="bibr" rid="ref21">21</xref>,<xref ref-type="bibr" rid="ref22">22</xref>]. Since simultaneous registrations of SEMG signals from the same location with different sets of surface electrodes are not possible, one set of electrodes from the stationary equipment was placed 2 cm cranially of the NeckSensor, and the other set was placed 2 cm caudally. The interelectrode distance was 4 cm. The “patient ground” electrode for the stationary equipment was placed over the spinous process C7 (<xref ref-type="fig" rid="figure1">Figure 1</xref>). The skin beneath the stationary electrodes was washed with alcohol swabs. The 2 skin temperature sensors were attached, without touching each other, to the volar pad of the distal phalange on the second finger with sticky tape, with the stationary sensor placed radially of the 2 sensor electrodes.</p>
        <p><xref ref-type="fig" rid="figure1">Figure 1</xref> shows the scheme of the electrode placements over the upper trapezius fibers. The wireless sensor electrode pair was placed first, midway in the line between the acromion and the spinous process C7. One of the two pairs of stationary sensor electrodes was placed cranially, whereas the other was placed caudally of the wireless sensor electrode pair. The interelectrode distance for each pair was 4 cm.</p>
        <p>Initially, each participant was asked to relax for 5 min to allow the skin temperature to increase during relaxation. Relaxation was achieved by asking the participant to do nothing and sit still on the recliner. This served to give a baseline (relaxed) muscle tension measurement. Relaxed trapezius muscle tension (baseline) was recorded in the last 30 s of relaxation. Thereafter, the temperature sensors were detached to allow the measurement of room temperature for the remainder of the procedure. Subsequently, the participant was instructed to complete a series of exercises to activate the upper fibers of the trapezius muscle. Arbitrary angle isometric maximal voluntary contraction (MVC), through shoulder elevation, was completed in 3 repetitions, each lasting for 6 s [<xref ref-type="bibr" rid="ref22">22</xref>-<xref ref-type="bibr" rid="ref25">25</xref>]. The SEMG and force were simultaneously registered. The force was recorded by a dynamometer (Manual Muscle Tester, Lafayette Instruments, USA) attached to a fixed sling placed over the acromion. Subsequently, the participant was asked to complete similar sets of contractions at 50% (VC50) and 25% (VC25) of maximal contraction guided by a sound signal from the dynamometer elicited at a corresponding set force. Finally, the participant was asked to complete 4 repetitions of static contractions (15 s each) performed by abducting both shoulders to a 90 degree angle and holding them against gravity [<xref ref-type="bibr" rid="ref22">22</xref>].</p>
        <p>After completing the exercises, the participant was asked to answer a 5‐item user evaluation questionnaire. Of these, 3 questions had reply options on a 5‐point Likert scale, ranging from “Very dissatisfied” to “Very satisfied,” while the remaining 2 questions were open for free comments (<xref ref-type="table" rid="table1">Table 1</xref>).</p>

        <fig id="figure1" position="float">
          <label>Figure 1</label>
          <caption>
            <p>Electrode placement.</p>
          </caption>
          <graphic xlink:href="biomedeng_v3i1e1_fig1.jpg" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>

        <table-wrap position="float" id="table1">
          <label>Table 1</label>
          <caption>
            <p>Evaluation questionnaire.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="50"/>
            <col width="950"/>
            <thead>
              <tr valign="top">
                <td>Item</td>
                <td>Question</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>1</td>
                <td>Did you perceive the wireless sensors as practical to use?</td>
              </tr>
              <tr valign="top">
                <td>2</td>
                <td>To what degree did you feel that the use of shoulder-musculature reflected the feedback in the app?</td>
              </tr>
              <tr valign="top">
                <td>3</td>
                <td>Do you recognize the wireless sensors as safe to use?</td>
              </tr>
              <tr valign="top">
                <td>4</td>
                <td>Did you experience any undesirable harmful effects (if yes, please explain)?</td>
              </tr>
              <tr valign="top">
                <td>5</td>
                <td>Do you have any further comments (if yes, please explain)?</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>

      </sec>
      <sec>
        <title>Data Management</title>
        <p>The NeckSensor uses a 12‐bit ADC resolution sampled at 1024 Hz with a third order 10‐480 Hz active bandpass filter. The sensor was programmed to calculate and transmit mean square values internally, with a window width of 40 ms, with no overlap, and a frequency of 25 Hz in order not to overload the Bluetooth capacity. The PowerLab sampled the SEMG signals at 2000 Hz with a fourth order Bessel lowpass filter at 500 Hz and a first order high pass filter at 10 Hz. In addition, a 50 Hz notch analog filter was applied [<xref ref-type="bibr" rid="ref26">26</xref>]. All stationary recordings were evaluated visually for the presence of ECG artifacts. If found, these were to be corrected by removing the spike-correlated area in the SEMG signal and subsequently replacing the gap with surrounding SEMG activity.</p>
        <p>First, the stationary readings were root mean square (RMS) rectified and then averaged over the two sets of electrodes to avoid phase-cancellations. The RMS value was calculated from the mean square values of the wireless sensors. The RMS values for each muscle contraction exercise to be used in the analyses were calculated as the mean of the repetitions for both equipment sets. For the temperature measurements, we calculated the difference in temperature from the start to the end of relaxation and the difference between the temperature at the end of relaxation and room temperature.</p>
      </sec>
      <sec>
        <title>Statistics</title>
        <p>The means and SD for the RMS values during trapezius muscle exercises and the chosen data temperature points were calculated. Systematic differences between stationary and wireless equipment were assessed with the Wilcoxon signed-rank test.</p>
        <p>Mean difference (MD) and limits of agreement (LOA), together with Bland-Altman plots were used as descriptive tools [<xref ref-type="bibr" rid="ref27">27</xref>].We calculated the intraclass correlation coefficient (ICC) with a two-way, mixed-effects consistency of agreement model. Coefficients for both individual and average agreement were presented. In addition, we calculated the Lin concordance correlation coefficient (CCC) [<xref ref-type="bibr" rid="ref28">28</xref>-<xref ref-type="bibr" rid="ref30">30</xref>]. For the ICC and CCC analyses, the data was first transformed to meet assumptions for a two-way analysis of variance model. Then the data was transformed by calculating the natural logarithm after adding 0.1 as a constant to adjust for values being close to zero. The ICC values were interpreted as suggested by Cicchetti et al [<xref ref-type="bibr" rid="ref31">31</xref>], that is, unacceptable or poor (.00‐.40), fair (.41‐.60), good (.61‐.75), and excellent (.75‐1.00). All data were analyzed by using the statistical package Stata version 14 (StataCorp, College Station, TX, USA).</p>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>Results</title>
      <sec>
        <title>Sensors and Software</title>
        <p>The WHMS fulfilling the predefined requirements were identified through pragmatic Internet-searches. The MVP version of the app used in the experimental procedure was programmed to receive data from the wireless sensors and feed raw data back to the user. The raw data were presented as two columns increasing in height with increase in muscle tension and temperature, respectively. The app was programmed to allow connection of any WHMS using Bluetooth.</p>
      </sec>
      <sec>
        <title>Participants</title>
        <p>A total of 20 healthy participants were recruited and completed the experimental procedure. Of these, 12 were male participants, and their mean age was 24.7 years (SD 2.7, range 18‐29 years).</p>
      </sec>
      <sec>
        <title>Surface Electromyography Sensor Agreement</title>
        <p>We observed no ECG artifacts in the SEMG recordings (<xref ref-type="fig" rid="figure2">Figure 2</xref>). Hence, the ECG-related elements were not removed from the SEMG recordings.</p>
        <p><xref ref-type="fig" rid="figure2">Figure 2</xref> shows the raw data of the SEMG activity for the wireless sensor (red), anterior stationary sensor (blue), and posterior stationary sensor (green) from a 24-year-old male participant. The marked areas indicate where the different exercises are performed. The figure exemplifies the absence of ECG artifacts and the similarity of the signals.</p>
        <p>Means and standard deviations of the RMS values for the trapezius muscle exercises are presented in <xref ref-type="table" rid="table2">Table 2</xref>. The wireless sensor showed a lower voltage during trapezius muscle exercises than during all contraction periods and at baseline.</p>
        <p><xref ref-type="table" rid="table3">Table 3</xref> summarizes the MD in millivolts (mV) between stationary and wireless equipment with corresponding LOA, for each of the exercises. Compared with the wireless equipment, the stationary equipment indicated a systematically higher voltage during MVC (0.25 mV), VC50 (0.11 mV), VC25 (0.06 mV), static hold (0.07 mV), and baseline (0.04 mV). A Bland-Altman plot, visually presenting the MD and LOA for VC25, is shown in <xref ref-type="fig" rid="figure3">Figure 3</xref>. <xref ref-type="table" rid="table3">Table 3</xref> also summarizes the ICC and CCC values for the SEMG equipment comparisons.</p>

        <fig id="figure2" position="float">
          <label>Figure 2</label>
          <caption>
            <p>Raw surface electromyography (SEMG) data. ECG: electrocardiogram; MVC: maximal voluntary contraction; RMS: root mean square; VC50: voluntary contraction at 50% force; VC25: voluntary contraction at 25% force.</p>
          </caption>
          <graphic xlink:href="biomedeng_v3i1e1_fig2.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>

        <table-wrap position="float" id="table2">
          <label>Table 2</label>
          <caption>
            <p>Comparison of the means for stationary and wireless equipment.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="400"/>
            <col width="200"/>
            <col width="200"/>
            <col width="200"/>
            <thead>
              <tr valign="bottom">
                <td>Exercise</td>
                <td>Stationary equipment (SD)</td>
                <td>Wireless equipment (SD)</td>
                <td>Z-value (<italic>P</italic> value)<sup>a</sup></td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>MVC<sup>b</sup></td>
                <td>0.62<sup>c</sup> (0.25)</td>
                <td>0.37 (0.15)</td>
                <td>3.73 (&#60;.001)</td>
              </tr>
              <tr valign="top">
                <td>VC50<sup>d</sup></td>
                <td>0.26 (0.11)</td>
                <td>0.15 (0.06)</td>
                <td>3.92 (&#60;.001)</td>
              </tr>
              <tr valign="top">
                <td>VC25<sup>e</sup></td>
                <td>0.15 (0.05)</td>
                <td>0.09 (0.05)</td>
                <td>3.73 (&#60;.001)</td>
              </tr>
              <tr valign="top">
                <td>Static hold</td>
                <td>0.16 (0.06)</td>
                <td>0.08 (0.03)</td>
                <td>3.85 (&#60;.001)</td>
              </tr>
              <tr valign="top">
                <td>Baseline</td>
                <td>0.045 (0.004)</td>
                <td>0.01 (0.002)</td>
                <td>3.92 (&#60;.001)</td>
              </tr>
              <tr valign="top">
                <td>Start temperature</td>
                <td>28.8<sup>f</sup> (3.4)</td>
                <td>28.8 (3.3)</td>
                <td>0.75 (=.46)</td>
              </tr>
              <tr valign="top">
                <td>End temperature</td>
                <td>30.7 (3.6)</td>
                <td>31.5 (4.0)</td>
                <td>3.4 (&#60;.001)</td>
              </tr>
              <tr valign="top">
                <td>Room temperature</td>
                <td>23.0 (0.3)</td>
                <td>23.6 (0.4)</td>
                <td>3.9 (&#60;.001)</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table2fn1">
              <p><sup>a</sup>Z-value from Wilcoxon signed-rank test.</p>
            </fn>
            <fn id="table2fn2">
              <p><sup>b</sup>MVC: maximal voluntary contraction.</p>
            </fn>
            <fn id="table2fn3">
              <p><sup>c</sup>Mean voltage in millivolts RMS.</p>
            </fn>
            <fn id="table2fn4">
              <p><sup>d</sup>VC50: voluntary contraction at 50% force.</p>
            </fn>
            <fn id="table2fn5">
              <p><sup>e</sup>VC25: voluntary contraction at 25% force.</p>
            </fn>
            <fn id="table2fn6">
              <p><sup>f</sup>Mean temperature in degrees Celsius.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>

        <table-wrap position="float" id="table3">
          <label>Table 3</label>
          <caption>
            <p>Indices of agreement between stationary and wireless equipment.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="200"/>
            <col width="125"/>
            <col width="150"/>
            <col width="175"/>
            <col width="175"/>
            <col width="165"/>
            <thead>
              <tr valign="bottom">
                <td>Exercise</td>
                <td>Mean difference</td>
                <td>Limits of agreement</td>
                <td>ICC<sup>a</sup> (95% CI) individual</td>
                <td>ICC (95% CI) average</td>
                <td>CCC<sup>b</sup> (95% CI)</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>MVC<sup>c</sup></td>
                <td>0.25<sup>f</sup></td>
                <td>−0.12 to 0.61</td>
                <td>.81 (0.57‐0.92)</td>
                <td>.89 (0.73‐0.96)</td>
                <td>.52 (0.30‐0.73)</td>
              </tr>
              <tr valign="top">
                <td>VC50<sup>d</sup></td>
                <td>0.11</td>
                <td>−0.04 to 0.27</td>
                <td>.81 (0.57‐0.92)</td>
                <td>.89 (0.73‐0.96)</td>
                <td>.44 (0.23‐0.64)</td>
              </tr>
              <tr valign="top">
                <td>VC25<sup>e</sup></td>
                <td>0.06</td>
                <td>−0.03 to 0.15</td>
                <td>.66 (0.31‐0.85)</td>
                <td>.79 (0.47‐0.92)</td>
                <td>.37 (0.14‐0.60)</td>
              </tr>
              <tr valign="top">
                <td>Static hold</td>
                <td>0.07</td>
                <td>−0.02 to 0.16</td>
                <td>.58 (0.19‐0.81)</td>
                <td>.73 (0.32‐0.89)</td>
                <td>.26 (0.06‐0.45)</td>
              </tr>
              <tr valign="top">
                <td>Baseline</td>
                <td>0.04</td>
                <td>0.03-0.04</td>
                <td>.50 (0.09‐0.77)</td>
                <td>.67 (0.16‐0.87)</td>
                <td>.01 (0.00‐0.01)</td>
              </tr>
              <tr valign="top">
                <td>Start to end temperature</td>
                <td>−0.77<sup>g</sup></td>
                <td>−1.90 to 0.35</td>
                <td>.96 (0.91‐0.99)</td>
                <td>.98 (0.95‐0.99)</td>
                <td>.90 (0.83‐0.97)</td>
              </tr>
              <tr valign="top">
                <td>End to room temperature</td>
                <td>−0.23</td>
                <td>−1.74 to 1.28</td>
                <td>.98 (0.95‐0.99)</td>
                <td>.99 (0.97‐1.0)</td>
                <td>.98 (0.96‐1.0)</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table3fn1">
              <p><sup>a</sup>ICC: intraclass correlation coefficient.</p>
            </fn>
            <fn id="table3fn2">
              <p><sup>b</sup>CCC: concordance correlation coefficient.</p>
            </fn>
            <fn id="table3fn3">
              <p><sup>c</sup>MVC: maximal voluntary contraction.</p>
            </fn>
            <fn id="table3fn4">
              <p><sup>d</sup>VC50: voluntary contraction at 50% force.</p>
            </fn>
            <fn id="table3fn5">
              <p><sup>e</sup>VC25: voluntary contraction at 25% force.</p>
            </fn>
            <fn id="table3fn6">
              <p><sup>f</sup>Mean voltage in millivolts RMS.</p>
            </fn>
            <fn id="table3fn7">
              <p><sup>g</sup>Mean temperature in degrees Celsius.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>

        <fig id="figure3" position="float">
          <label>Figure 3</label>
          <caption>
            <p>Surface electromyography (SEMG) sensor agreement. mV: millivolts; RMS: root mean square.</p>
          </caption>
          <graphic xlink:href="biomedeng_v3i1e1_fig3.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>

        <p>Excellent agreement was found for MVC (ICC .81, 95% CI 0.57‐0.92) and VC50 (ICC .81, 95% CI 0.57‐0.92). Good agreement was found for VC25 (ICC .66, 95% CI 0.31‐0.85). Fair agreement was found for static hold (ICC .58, 95% CI 0.19‐0.81) and baseline (ICC .50, 95% CI 0.09‐0.77). All participants displayed a decrease in voltage from MVC to VC50, from VC50 to VC25, and from static hold to baseline for both sets of equipment, with the exception of one participant who had a small increase (0.03 mV) in voltage from VC50 to VC25 registered on the stationary equipment (<xref ref-type="fig" rid="figure4">Figure 4</xref>).</p>
        <p><xref ref-type="fig" rid="figure3">Figure 3</xref> shows Bland-Altman plot assessing the agreement between stationary and wireless SEMG sensors during voluntary contraction at 25% force. The x-axis represents the average of the two parallel measurements. The y-axis represents the corresponding difference between the 2 measurements. The values are indicated in millivolt RMS.</p>
        <p><xref ref-type="fig" rid="figure4">Figure 4</xref> is a line graph showing the SEMG readings for each participant during MVC, VC50, VC25, static hold, and baseline. The top panel indicates readings with the stationary equipment. The bottom panel indicates readings with the wireless equipment. The values are indicated in millivolt RMS.</p>
      </sec>
      <sec>
        <title>Peripheral Skin Temperature Sensor Agreement</title>
        <p>Means and standard deviations of the temperature measurements at the 3 selected time points are shown in <xref ref-type="table" rid="table2">Table 2</xref>. The start temperature between the 2 sets of equipment did not differ significantly (<italic>P</italic>=.46), but the wireless sensor indicated a higher temperature at the end of relaxation (<italic>P</italic>&#60;.001) and at room temperature (<italic>P</italic>&#60;.001; <xref ref-type="table" rid="table2">Table 2</xref>).</p>
        <p>The between-equipment MDs for changes in the temperature are presented in <xref ref-type="table" rid="table3">Table 3</xref>, along with the LOA and agreement indices. A Bland-Altman plot visually representing the MD and LOA for temperature change during relaxation is depicted in <xref ref-type="fig" rid="figure5">Figure 5</xref>. Excellent agreement was found for the change in temperature during relaxation (CCC .90, 95% CI 0.83‐0.97) and from end of relaxation to room temperature (CCC .98, 95% CI 0.96‐1.0). A rise in temperature was detected among 17 participants on the stationary equipment, and among 18 participants on the wireless equipment. Moreover, a rise in temperature of more than 1°C was detected among 15 participants on both equipment sets (<xref ref-type="fig" rid="figure6">Figure 6</xref>).</p>
        <p><xref ref-type="fig" rid="figure5">Figure 5</xref> is a Bland-Altman plot showing the agreement between stationary and wireless equipment for the change in temperature from start to end of relaxation. The x-axis represents the average of the 2 parallel measurements. The y-axis represents the corresponding difference in measurements. The values are in degrees Celsius.</p>
        <p><xref ref-type="fig" rid="figure6">Figure 6</xref> is a line graph showing temperature readings for each participant at the start and end of relaxation and at room temperature. The upper panel represents readings with the stationary equipment. The lower panel represents readings with the wireless equipment. The values are in degrees Celsius.</p>
      </sec>
      <sec>
        <title>Evaluation Questionnaire</title>
        <p>In total, 19 of the 20 participants perceived the use of wireless sensors as practical (n=14) or very practical (n=5). Likewise, the absolute majority of participants reported that the app feedback reflected the use of shoulder musculature to a large (n=9) or a very large (n=9) degree. All participants regarded the use of wireless sensors as safe (n=2) or very safe (n=18). In contrast, 2 of the 20 participants reported undesirable, harmful effects, with both stating that the removal of the electrodes attached to the stationary equipment was unpleasant.</p>

        <fig id="figure4" position="float">
          <label>Figure 4</label>
          <caption>
            <p>Surface electromyography (SEMG) sensor line graphs. mV: millivolts; MVC: maximal voluntary contraction; RMS: root mean square; VC50: voluntary contraction at 50% force; VC25: voluntary contraction at 25% force.</p>
          </caption>
          <graphic xlink:href="biomedeng_v3i1e1_fig4.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>

        <fig id="figure5" position="float">
          <label>Figure 5</label>
          <caption>
            <p>Temperature sensor agreement. mV: millivolts; RMS: root mean square.</p>
          </caption>
          <graphic xlink:href="biomedeng_v3i1e1_fig5.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>

        <fig id="figure6" position="float">
          <label>Figure 6</label>
          <caption>
            <p>Temperature sensor line graphs.</p>
          </caption>
          <graphic xlink:href="biomedeng_v3i1e1_fig6.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
      </sec>
    </sec>
    <sec sec-type="discussion">
      <title>Discussion</title>
      <sec>
        <title>Principal Findings</title>
        <p>This study aimed to provide a proof of concept for using a mobile phone and WHMS for biofeedback purposes, in a fashion similar to phase I-II development of new drug treatments [<xref ref-type="bibr" rid="ref32">32</xref>]. We chose to investigate temperature and SMEG because they are the most commonly used biofeedback modalities [<xref ref-type="bibr" rid="ref11">11</xref>] and are shown to be especially effective in adolescents [<xref ref-type="bibr" rid="ref33">33</xref>]. We identified sensors fulfilling a set of predefined criteria that were considered necessary for the sensors to gain acceptance among patients, and thus these sensors were used [<xref ref-type="bibr" rid="ref34">34</xref>]. The choice of sensors was arbitrary, as long as the predefined criteria were met. Even though the use of other temperature and SEMG sensors would not yield identical results, we argue that our approach has provided a proof of concept.</p>
        <p>We found that the use of a wireless temperature sensor had almost perfect agreement regarding the change in finger temperature during relaxation. Furthermore, the use of a wireless SEMG sensor had a fair to excellent agreement for measuring tension in the trapezius muscle. We noted that the wireless SEMG consistently showed a lower voltage than the stationary equipment. The SEMG sensors showed excellent agreement during MVC and VC50, good agreement during VC25, and fair agreement during static hold and baseline. However, under the assumption that the stationary equipment was the most sensitive, it is not surprising that the calculated agreement decreased slightly at lower activity levels since random and equipment-generated noise constituted a larger part of the signal at low EMG-levels. Nonetheless, the wireless SEMG sensor registered consistent changes in muscle tension. We observed no ECG artifacts in the SEMG recordings. Therefore, it can be assumed that the ECG artifacts do not have a relevant influence on the SEMG recorded from closely placed bipolar electrodes on the right shoulder. Moreover, the safety and usability of the setup were highly satisfactory. In conclusion, the wireless sensors are well suited for biofeedback purposes.</p>
      </sec>
      <sec>
        <title>Strengths and Limitations</title>
        <p>The proper sample size for the study was assessed before recruiting participants (<xref ref-type="app" rid="app1">Multimedia Appendix 1</xref>). Traditionally, a sample of 15 to 20 participants is deemed sufficient for reliability studies [<xref ref-type="bibr" rid="ref35">35</xref>]. However, the use of more precise calculations of sample sizes has been previously suggested [<xref ref-type="bibr" rid="ref36">36</xref>]. Therefore, we used a CI estimation model suggested by Bonett [<xref ref-type="bibr" rid="ref20">20</xref>] to determine the minimum sample size required. Due to the interindividual variation in our findings, the analyses would possibly have benefited from having a larger sample size because we did not obtain a predefined CI for all analyses.</p>
        <p>There is a large degree of variability in individual human anatomical properties that may influence SEMG readings. This includes the thickness of fatty tissues, resting muscle length, velocity of contraction, muscle cross-sectional area, fiber type, posture change, interelectrode distance, skin impedance, age, and sex [<xref ref-type="bibr" rid="ref22">22</xref>]. We chose to combine the recordings for the 2 pairs of stationary sensor electrodes to approximate the muscle activity of the wireless sensor placed in between. The relative spread of the electrode pairs may have led to EMG crosstalk, and muscle contraction exercises performed by untrained participants may have additionally resulted in movement artifacts, and suboptimal and varying performances [<xref ref-type="bibr" rid="ref37">37</xref>]. The abovementioned factors may all have limited the precision of our measurements and contributed to a larger degree of interindividual differences, thus lowering individual ICC and CCC values for SEMG agreement. Likewise, the placement of the 2 temperature sensors beside each other on the finger might have led to differences in measurements. <xref ref-type="fig" rid="figure5">Figure 5</xref> shows 1 outlier that displayed a larger increase in temperature by 1°C with the stationary equipment than with the wireless equipment. This differs from the majority that displayed the largest temperature increase with the wireless equipment. Nevertheless, LOA of ±1.5°C is still acceptable [<xref ref-type="bibr" rid="ref38">38</xref>].</p>
        <p>The SEMG signals usually have a frequency distribution with significant energy up to 400 to 500 Hz, requiring a sampling frequency of at least 1000 Hz (preferably 2000 Hz) to meet the Nyquist rate (2 times higher signal frequency) and avoid the so-called aliasing [<xref ref-type="bibr" rid="ref39">39</xref>]. However, it is known that oversampling above this critical Nyquist rate does not significantly improve the signal quality [<xref ref-type="bibr" rid="ref40">40</xref>] but will likely lead to higher cost and size of the sensor. The SEMG signals are usually bandpass filtered at 10 to 500 Hz [<xref ref-type="bibr" rid="ref41">41</xref>], which we consequently chose to do for both setups. Furthermore, we observed that the notch filter, at 50 Hz, for the stationary equipment seemed to be saturated during recordings. After analog filtering, sine waves of 20 ms duration were still present. This may be explained by power-line noise, despite the use of a notch filter [<xref ref-type="bibr" rid="ref42">42</xref>]. The wireless sensor also applies a notch filter at 50 Hz, which increases the signal-to-noise ratio. In total, we concluded that the wireless SEMG sensor applies appropriate signal processing settings.</p>
        <p>We chose different statistical methods for assessing agreement to evaluate different properties of the wireless sensors. The Wilcoxon signed-ranks tests, together with the Bland-Altman plot and LOA, assess the degree of systematic differences and expected variance between measurements. A two-way, mixed-effect ICC model [<xref ref-type="bibr" rid="ref43">43</xref>] ignores the element of rater variance (raters fixed as the 2 equipment sets), and the estimate can thus serve as an index of consistency [<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref30">30</xref>,<xref ref-type="bibr" rid="ref44">44</xref>,<xref ref-type="bibr" rid="ref45">45</xref>]. This is useful to assess agreement when having mean differences between 2 measurement methods. We reported both individual and average ICC values, as the average value becomes useful when a large degree of interindividual variance exists or if individual readings are considered unreliable [<xref ref-type="bibr" rid="ref30">30</xref>]. On the other hand, we also calculated the CCC to evaluate the degree of absolute agreement, that is, the 2 measurement methods showing identical values.</p>
      </sec>
      <sec>
        <title>Interpretation</title>
        <p>We have compared the WHMS with a gold standard; however, this does not imply that the gold standard is without measurement error. Thus, some lack of agreement is inevitable [<xref ref-type="bibr" rid="ref46">46</xref>]. As pointed out by Bland and Altman [<xref ref-type="bibr" rid="ref47">47</xref>], one should keep in mind that correlation coefficients alone do not assess interchangeability of measurement methods. The acceptable level of agreement in order to claim validity is a clinical decision. Considering the intended use of the chosen sensors, a high degree of absolute agreement is not a necessity, but consistency of agreement is important. We certainly observed that there exists variance in the data, leading to a low degree of absolute agreement. On the other hand, SEMG readings changed similarly and as expected through the experimental procedure for each participant, despite dissimilarities between the 2 equipment sets. This consistency is indeed supported by excellent to fair agreement of ICC values. Furthermore, the wireless SEMG sensor was less reliable at lower voltage, at least in terms of absolute agreement, when compared with our gold standard. A well-designed SEMG setup usually produces a system noise of about 1% of the MVC [<xref ref-type="bibr" rid="ref48">48</xref>]. Our stationary equipment baseline showed 7% of MVC, which means that there was some inherent noise in the gold standard setup. In contrast, the baseline readings of the wireless sensors amounted to 3% of MVC, which in part may explain the increasing deviation at lower voltages.</p>
        <p>Although the SEMG sensor did not demonstrate excellent agreement in all analyses, both SEMG and temperature WHMS appear to be suited for app-based biofeedback. Interestingly, 15 out of 20 participants (75%) managed to raise their temperature by more than 1°C during a single naive session indicating that the setup was simple to master. Moreover, all participants had similar changes in muscle tension through the sets of exercises. However, it is unlikely that the users will be able to decrease their muscle tension throughout the entire duration of a biofeedback session [<xref ref-type="bibr" rid="ref49">49</xref>]. This means that detecting a change in tension is more important than the absolute values. In line with this, it was recently shown that the feedback itself is more important than lowering muscle tension in the treatment of headache [<xref ref-type="bibr" rid="ref50">50</xref>]. Taken together, these findings imply that perfect sensor agreement in itself is not a prerequisite for an app-based biofeedback platform. The main focus of app-based biofeedback should be directed at the development of high-quality feedback mechanisms and user interfaces.</p>
      </sec>
      <sec>
        <title>Prospects for Future Research</title>
        <p>This study confirmed the usability of WHMS in a biofeedback setting and established partial evidence for an upcoming biofeedback app. At any rate, the scientific validation of the sensor is of utmost importance for the value and effectiveness of a future treatment program. The choice to use an MVP app to assess agreement enables iterative and incremental developments. Future research should be carried out to establish further the basis for the use of WHMS for medical purposes in the emerging era of health informatics and mHealth. As an example, similar validation of heart rate variability measurements, which is of interest in biofeedback treatment, has been conducted [<xref ref-type="bibr" rid="ref51">51</xref>,<xref ref-type="bibr" rid="ref52">52</xref>,<xref ref-type="bibr" rid="ref53">53</xref>]. We are currently exploring the user interface and assessing the usability of the app among adolescents with migraine.</p>
      </sec>
      <sec>
        <title>Conclusions</title>
        <p>This study confirmed the validity of wireless WHMS connected to a mobile phone for monitoring neurophysiological parameters of relevance for biofeedback therapy.</p>
      </sec>
    </sec>
  </body>
  <back>
    <app-group>
      <app id="app1">
        <title>Multimedia Appendix 1</title>
        <p>Sample size determination.</p>
        <media xlink:href="biomedeng_v3i1e1_app1.pdf" xlink:title="PDF File (Adobe PDF File), 32KB"/>
      </app>
    </app-group>
    <glossary>
      <title>Abbreviations</title>
      <def-list>
        <def-item>
          <term id="abb1">CCC</term>
          <def>
            <p>concordance correlation coefficient</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb2">ECG</term>
          <def>
            <p>electrocardiogram</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb3">ICC</term>
          <def>
            <p>intraclass correlation coefficient</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb4">LOA</term>
          <def>
            <p>limits of agreement</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb5">MD</term>
          <def>
            <p>mean difference</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb6">mHealth</term>
          <def>
            <p>mobile health</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb7">MVC</term>
          <def>
            <p>maximal voluntary contraction</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb8">MVP</term>
          <def>
            <p>minimal viable product</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb9">RMS</term>
          <def>
            <p>root mean square</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb10">SEMG</term>
          <def>
            <p>surface electromyography</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb11">VC50</term>
          <def>
            <p>voluntary contraction at 50% force</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb12">VC25</term>
          <def>
            <p>voluntary contraction at 25% force</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb13">WHMS</term>
          <def>
            <p>wearable health monitoring sensors</p>
          </def>
        </def-item>
      </def-list>
    </glossary>
    <ack>
      <p>The authors wish to thank all the volunteers for participating in the study. The study was funded by strategic seeding grants from the Faculty of Medicine, NTNU Norwegian University of Science and Technology. We would also like to thank Searis AS for the fruitful collaboration and for their help with programming the app, EXPAIN AS for supplying SEMG sensors for use in the study, and the personnel at the Department of Neurophysiology, St Olavs Hospital, for their support with the experimental procedures.</p>
    </ack>
    <fn-group>
      <fn fn-type="conflict">
        <p>Anker Stubberud has participated as a nonpaid member of an Expert Panel advising EXPAIN AS during the final phases of product development. Should the research result in a commercially available product, the university and authors may benefit financially from future intellectual property rights.</p>
      </fn>
    </fn-group>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <nlm-citation citation-type="web">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Kay</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Santos</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Takane</surname>
            <given-names>M</given-names>
          </name>
        </person-group>
        <source>Who.int</source>  
        <year>2011</year>  
        <access-date>2018-02-13</access-date>
        <comment>mHealth: new horizons for health through mobile technologies 
        <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://www.who.int/goe/publications/goe_mhealth_web.pdf">http://www.who.int/goe/publications/goe_mhealth_web.pdf</ext-link>
        <ext-link ext-link-type="webcite" xlink:href="6xCFk9ovq"/></comment> </nlm-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Pantelopoulos</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Bourbakis</surname>
            <given-names>NG</given-names>
          </name>
        </person-group>
        <article-title>A survey on wearable sensor-based systems for health monitoring and prognosis</article-title>
        <source>IEEE Trans Syst Man Cybern C Appl Rev</source>  
        <year>2010</year>  
        <volume>40</volume>  
        <issue>1</issue>  
        <fpage>1</fpage>  
        <lpage>12</lpage>  
        <pub-id pub-id-type="doi">10.1109/TSMCC.2009.2032660</pub-id></nlm-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Dobkin</surname>
            <given-names>BH</given-names>
          </name>
          <name name-style="western">
            <surname>Dorsch</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>The promise of mHealth: daily activity monitoring and outcome assessments by wearable sensors</article-title>
        <source>Neurorehabil Neural Repair</source>  
        <year>2011</year>  
        <volume>25</volume>  
        <issue>9</issue>  
        <fpage>788</fpage>  
        <lpage>98</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/21989632"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1177/1545968311425908</pub-id>
        <pub-id pub-id-type="medline">21989632</pub-id>
        <pub-id pub-id-type="pii">25/9/788</pub-id>
        <pub-id pub-id-type="pmcid">PMC4098920</pub-id></nlm-citation>
      </ref>
      <ref id="ref4">
        <label>4</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Hanson</surname>
            <given-names>MA</given-names>
          </name>
          <name name-style="western">
            <surname>Powell Jr</surname>
            <given-names>HC</given-names>
          </name>
          <name name-style="western">
            <surname>Barth</surname>
            <given-names>AT</given-names>
          </name>
          <name name-style="western">
            <surname>Ringenberg</surname>
            <given-names>K</given-names>
          </name>
          <name name-style="western">
            <surname>Calhoun</surname>
            <given-names>BH</given-names>
          </name>
          <name name-style="western">
            <surname>Aylor</surname>
            <given-names>JH</given-names>
          </name>
          <name name-style="western">
            <surname>Lach</surname>
            <given-names>J</given-names>
          </name>
        </person-group>
        <article-title>Body area sensor networks: challenges and opportunities</article-title>
        <source>Computer</source>  
        <year>2009</year>  
        <volume>42</volume>  
        <issue>1</issue>  
        <fpage>58</fpage>  
        <lpage>65</lpage> </nlm-citation>
      </ref>
      <ref id="ref5">
        <label>5</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Schüll</surname>
            <given-names>ND</given-names>
          </name>
        </person-group>
        <article-title>Data for life: wearable technology and the design of self-care</article-title>
        <source>BioSocieties</source>  
        <year>2016</year>  
        <volume>11</volume>  
        <issue>3</issue>  
        <fpage>317</fpage>  
        <lpage>333</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://arts.mit.edu/wp-content/uploads/2016/11/Data-for-Life-Wearable-Technology-and-the-Design-of-Self-Care.pdf"/>
        </comment> </nlm-citation>
      </ref>
      <ref id="ref6">
        <label>6</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Lupton</surname>
            <given-names>D</given-names>
          </name>
        </person-group>
        <article-title>Quantifying the body: monitoring and measuring health in the age of mHealth technologies</article-title>
        <source>Crit Public Health</source>  
        <year>2013</year>  
        <volume>23</volume>  
        <issue>4</issue>  
        <fpage>393</fpage>  
        <lpage>403</lpage>  
        <pub-id pub-id-type="doi">10.1080/09581596.2013.794931</pub-id></nlm-citation>
      </ref>
      <ref id="ref7">
        <label>7</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Hundert</surname>
            <given-names>AS</given-names>
          </name>
          <name name-style="western">
            <surname>Huguet</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>McGrath</surname>
            <given-names>PJ</given-names>
          </name>
          <name name-style="western">
            <surname>Stinson</surname>
            <given-names>JN</given-names>
          </name>
          <name name-style="western">
            <surname>Wheaton</surname>
            <given-names>M</given-names>
          </name>
        </person-group>
        <article-title>Commercially available mobile phone headache diary apps: a systematic review</article-title>
        <source>JMIR Mhealth Uhealth</source>  
        <year>2014</year>  
        <volume>2</volume>  
        <issue>3</issue>  
        <fpage>e36</fpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://mhealth.jmir.org/2014/3/e36/"/>
        </comment>  
        <pub-id pub-id-type="doi">10.2196/mhealth.3452</pub-id>
        <pub-id pub-id-type="medline">25138438</pub-id>
        <pub-id pub-id-type="pii">v2i3e36</pub-id>
        <pub-id pub-id-type="pmcid">PMC4147710</pub-id></nlm-citation>
      </ref>
      <ref id="ref8">
        <label>8</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Fiordelli</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Diviani</surname>
            <given-names>N</given-names>
          </name>
          <name name-style="western">
            <surname>Schulz</surname>
            <given-names>PJ</given-names>
          </name>
        </person-group>
        <article-title>Mapping mHealth research: a decade of evolution</article-title>
        <source>J Med Internet Res</source>  
        <year>2013</year>  
        <volume>15</volume>  
        <issue>5</issue>  
        <fpage>e95</fpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://www.jmir.org/2013/5/e95/"/>
        </comment>  
        <pub-id pub-id-type="doi">10.2196/jmir.2430</pub-id>
        <pub-id pub-id-type="medline">23697600</pub-id>
        <pub-id pub-id-type="pii">v15i5e95</pub-id>
        <pub-id pub-id-type="pmcid">PMC3668610</pub-id></nlm-citation>
      </ref>
      <ref id="ref9">
        <label>9</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Penzien</surname>
            <given-names>DB</given-names>
          </name>
          <name name-style="western">
            <surname>Irby</surname>
            <given-names>MB</given-names>
          </name>
          <name name-style="western">
            <surname>Smitherman</surname>
            <given-names>TA</given-names>
          </name>
          <name name-style="western">
            <surname>Rains</surname>
            <given-names>JC</given-names>
          </name>
          <name name-style="western">
            <surname>Houle</surname>
            <given-names>TT</given-names>
          </name>
        </person-group>
        <article-title>Well-established and empirically supported behavioral treatments for migraine</article-title>
        <source>Curr Pain Headache Rep</source>  
        <year>2015</year>  
        <month>07</month>  
        <volume>19</volume>  
        <issue>7</issue>  
        <fpage>34</fpage>  
        <pub-id pub-id-type="doi">10.1007/s11916-015-0500-5</pub-id>
        <pub-id pub-id-type="medline">26065542</pub-id></nlm-citation>
      </ref>
      <ref id="ref10">
        <label>10</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Stubberud</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Varkey</surname>
            <given-names>E</given-names>
          </name>
          <name name-style="western">
            <surname>McCrory</surname>
            <given-names>DC</given-names>
          </name>
          <name name-style="western">
            <surname>Pedersen</surname>
            <given-names>SA</given-names>
          </name>
          <name name-style="western">
            <surname>Linde</surname>
            <given-names>M</given-names>
          </name>
        </person-group>
        <article-title>Biofeedback as prophylaxis for pediatric migraine: a meta-analysis</article-title>
        <source>Pediatrics</source>  
        <year>2016</year>  
        <month>08</month>  
        <volume>138</volume>  
        <issue>2</issue>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://pediatrics.aappublications.org/cgi/pmidlookup?view=long&#38;pmid=27462067"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1542/peds.2016-0675</pub-id>
        <pub-id pub-id-type="medline">27462067</pub-id>
        <pub-id pub-id-type="pii">peds.2016-0675</pub-id></nlm-citation>
      </ref>
      <ref id="ref11">
        <label>11</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Nestoriuc</surname>
            <given-names>Y</given-names>
          </name>
          <name name-style="western">
            <surname>Martin</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>Efficacy of biofeedback for migraine: a meta-analysis</article-title>
        <source>Pain</source>  
        <year>2007</year>  
        <month>03</month>  
        <volume>128</volume>  
        <issue>1-2</issue>  
        <fpage>111</fpage>  
        <lpage>27</lpage>  
        <pub-id pub-id-type="doi">10.1016/j.pain.2006.09.007</pub-id>
        <pub-id pub-id-type="medline">17084028</pub-id>
        <pub-id pub-id-type="pii">S0304-3959(06)00465-9</pub-id></nlm-citation>
      </ref>
      <ref id="ref12">
        <label>12</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Andrasik</surname>
            <given-names>F</given-names>
          </name>
        </person-group>
        <article-title>Behavioral treatment of headaches: extending the reach</article-title>
        <source>Neurol Sci</source>  
        <year>2012</year>  
        <month>05</month>  
        <volume>33 Suppl 1</volume>  
        <fpage>S127</fpage>  
        <lpage>30</lpage>  
        <pub-id pub-id-type="doi">10.1007/s10072-012-1073-2</pub-id>
        <pub-id pub-id-type="medline">22644187</pub-id></nlm-citation>
      </ref>
      <ref id="ref13">
        <label>13</label>
        <nlm-citation citation-type="book">
        <person-group person-group-type="editor">
          <name name-style="western">
            <surname>Schwartz</surname>
            <given-names>MS</given-names>
          </name>
          <name name-style="western">
            <surname>Andrasik</surname>
            <given-names>F</given-names>
          </name>
        </person-group>
        <source>Biofeedback: A Practitioner's Guide</source>  
        <year>2017</year>  
        <publisher-loc>New York City</publisher-loc>
        <publisher-name>Guilford Press</publisher-name></nlm-citation>
      </ref>
      <ref id="ref14">
        <label>14</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Minen</surname>
            <given-names>MT</given-names>
          </name>
          <name name-style="western">
            <surname>Torous</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Raynowska</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Piazza</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Grudzen</surname>
            <given-names>C</given-names>
          </name>
          <name name-style="western">
            <surname>Powers</surname>
            <given-names>S</given-names>
          </name>
          <name name-style="western">
            <surname>Lipton</surname>
            <given-names>R</given-names>
          </name>
          <name name-style="western">
            <surname>Sevick</surname>
            <given-names>MA</given-names>
          </name>
        </person-group>
        <article-title>Electronic behavioral interventions for headache: a systematic review</article-title>
        <source>J Headache Pain</source>  
        <year>2016</year>  
        <volume>17</volume>  
        <fpage>51</fpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="https://link.springer.com/article/10.1186/s10194-016-0608-y"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1186/s10194-016-0608-y</pub-id>
        <pub-id pub-id-type="medline">27160107</pub-id>
        <pub-id pub-id-type="pii">10.1186/s10194-016-0608-y</pub-id>
        <pub-id pub-id-type="pmcid">PMC4864730</pub-id></nlm-citation>
      </ref>
      <ref id="ref15">
        <label>15</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Luxton</surname>
            <given-names>DD</given-names>
          </name>
          <name name-style="western">
            <surname>McCann</surname>
            <given-names>RA</given-names>
          </name>
          <name name-style="western">
            <surname>Mishkind</surname>
            <given-names>MC</given-names>
          </name>
          <name name-style="western">
            <surname>Reger</surname>
            <given-names>GM</given-names>
          </name>
          <name name-style="western">
            <surname>Bush</surname>
            <given-names>NE</given-names>
          </name>
        </person-group>
        <article-title>mHealth for mental health: integrating smartphone technology in behavioral healthcare</article-title>
        <source>Prof Psychol Res Pr</source>  
        <year>2011</year>  
        <volume>42</volume>  
        <issue>6</issue>  
        <fpage>505</fpage>  
        <lpage>12</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://citeseerx.ist.psu.edu/viewdoc/download?doi=10.1.1.648.7052&#38;rep=rep1&#38;type=pdf"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1037/a0024485</pub-id></nlm-citation>
      </ref>
      <ref id="ref16">
        <label>16</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Constantinescu</surname>
            <given-names>G</given-names>
          </name>
          <name name-style="western">
            <surname>Loewen</surname>
            <given-names>I</given-names>
          </name>
          <name name-style="western">
            <surname>King</surname>
            <given-names>B</given-names>
          </name>
          <name name-style="western">
            <surname>Hodgetts</surname>
            <given-names>W</given-names>
          </name>
          <name name-style="western">
            <surname>Rieger</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Brodt</surname>
            <given-names>C</given-names>
          </name>
        </person-group>
        <article-title>Designing a mobile health app for patients with dysphagia following head and neck cancer: a qualitative study</article-title>
        <source>JMIR Rehabil Assist Technol</source>  
        <year>2017</year>  
        <volume>4</volume>  
        <issue>1</issue>  
        <fpage>e3</fpage>  
        <pub-id pub-id-type="medline">28582245</pub-id></nlm-citation>
      </ref>
      <ref id="ref17">
        <label>17</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>O'Reilly</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Duffin</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Ward</surname>
            <given-names>T</given-names>
          </name>
          <name name-style="western">
            <surname>Caulfield</surname>
            <given-names>B</given-names>
          </name>
        </person-group>
        <article-title>Mobile app to streamline the development of wearable sensor-based exercise biofeedback systems: system development and evaluation</article-title>
        <source>JMIR Rehabil Assist Technol</source>  
        <year>2017</year>  
        <volume>4</volume>  
        <issue>2</issue>  
        <fpage>e9</fpage>  
        <pub-id pub-id-type="doi">10.2196/rehab.7259</pub-id></nlm-citation>
      </ref>
      <ref id="ref18">
        <label>18</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Kottner</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Audige</surname>
            <given-names>L</given-names>
          </name>
          <name name-style="western">
            <surname>Brorson</surname>
            <given-names>S</given-names>
          </name>
          <name name-style="western">
            <surname>Donner</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Gajewski</surname>
            <given-names>BJ</given-names>
          </name>
          <name name-style="western">
            <surname>Hróbjartsson</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Roberts</surname>
            <given-names>C</given-names>
          </name>
          <name name-style="western">
            <surname>Shoukri</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Streiner</surname>
            <given-names>DL</given-names>
          </name>
        </person-group>
        <article-title>Guidelines for reporting reliability and agreement studies (GRRAS) were proposed</article-title>
        <source>Int J Nurs Stud</source>  
        <year>2011</year>  
        <month>06</month>  
        <volume>48</volume>  
        <issue>6</issue>  
        <fpage>661</fpage>  
        <lpage>71</lpage>  
        <pub-id pub-id-type="doi">10.1016/j.ijnurstu.2011.01.016</pub-id>
        <pub-id pub-id-type="medline">21514934</pub-id>
        <pub-id pub-id-type="pii">S0020-7489(11)00036-8</pub-id></nlm-citation>
      </ref>
      <ref id="ref19">
        <label>19</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Larman</surname>
            <given-names>C</given-names>
          </name>
          <name name-style="western">
            <surname>Basili</surname>
            <given-names>VR</given-names>
          </name>
        </person-group>
        <article-title>Iterative and incremental developments: a brief history</article-title>
        <source>Comput</source>  
        <year>2003</year>  
        <volume>36</volume>  
        <issue>6</issue>  
        <fpage>47</fpage>  
        <lpage>56</lpage>  
        <pub-id pub-id-type="doi">10.1109/MC.2003.1204375</pub-id></nlm-citation>
      </ref>
      <ref id="ref20">
        <label>20</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bonett</surname>
            <given-names>DG</given-names>
          </name>
        </person-group>
        <article-title>Sample size requirements for estimating intraclass correlations with desired precision</article-title>
        <source>Stat Med</source>  
        <year>2002</year>  
        <month>05</month>  
        <day>15</day>  
        <volume>21</volume>  
        <issue>9</issue>  
        <fpage>1331</fpage>  
        <lpage>5</lpage>  
        <pub-id pub-id-type="doi">10.1002/sim.1108</pub-id>
        <pub-id pub-id-type="medline">12111881</pub-id></nlm-citation>
      </ref>
      <ref id="ref21">
        <label>21</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Hermens</surname>
            <given-names>HJ</given-names>
          </name>
          <name name-style="western">
            <surname>Freriks</surname>
            <given-names>B</given-names>
          </name>
          <name name-style="western">
            <surname>Disselhorst-Klug</surname>
            <given-names>C</given-names>
          </name>
          <name name-style="western">
            <surname>Rau</surname>
            <given-names>G</given-names>
          </name>
        </person-group>
        <article-title>Development of recommendations for SEMG sensors and sensor placement procedures</article-title>
        <source>J Electromyogr Kinesiol</source>  
        <year>2000</year>  
        <month>10</month>  
        <volume>10</volume>  
        <issue>5</issue>  
        <fpage>361</fpage>  
        <lpage>74</lpage>  
        <pub-id pub-id-type="medline">11018445</pub-id>
        <pub-id pub-id-type="pii">S1050-6411(00)00027-4</pub-id></nlm-citation>
      </ref>
      <ref id="ref22">
        <label>22</label>
        <nlm-citation citation-type="book">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Criswell</surname>
            <given-names>E</given-names>
          </name>
        </person-group>
        <source>Cram's Introduction to Surface Electromyography. 2nd edition</source>  
        <year>2010</year>  
        <publisher-loc>Sudbury, MA</publisher-loc>
        <publisher-name>Jones &#38; Bartlett Publishers</publisher-name></nlm-citation>
      </ref>
      <ref id="ref23">
        <label>23</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Mathiassen</surname>
            <given-names>SE</given-names>
          </name>
          <name name-style="western">
            <surname>Winkel</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Hägg</surname>
            <given-names>GM</given-names>
          </name>
        </person-group>
        <article-title>Normalization of surface EMG amplitude from the upper trapezius muscle in ergonomic studies - A review</article-title>
        <source>J Electromyogr Kinesiol</source>  
        <year>1995</year>  
        <month>12</month>  
        <volume>5</volume>  
        <issue>4</issue>  
        <fpage>197</fpage>  
        <lpage>226</lpage>  
        <pub-id pub-id-type="medline">20719652</pub-id>
        <pub-id pub-id-type="pii">1050-6411(94)00014-X</pub-id></nlm-citation>
      </ref>
      <ref id="ref24">
        <label>24</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Burden</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>How should we normalize electromyograms obtained from healthy participants? What we have learned from over 25 years of research</article-title>
        <source>J Electromyogr Kinesiol</source>  
        <year>2010</year>  
        <month>12</month>  
        <volume>20</volume>  
        <issue>6</issue>  
        <fpage>1023</fpage>  
        <lpage>35</lpage>  
        <pub-id pub-id-type="doi">10.1016/j.jelekin.2010.07.004</pub-id>
        <pub-id pub-id-type="medline">20702112</pub-id>
        <pub-id pub-id-type="pii">S1050-6411(10)00100-8</pub-id></nlm-citation>
      </ref>
      <ref id="ref25">
        <label>25</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Knutson</surname>
            <given-names>LM</given-names>
          </name>
          <name name-style="western">
            <surname>Soderberg</surname>
            <given-names>GL</given-names>
          </name>
          <name name-style="western">
            <surname>Ballantyne</surname>
            <given-names>BT</given-names>
          </name>
          <name name-style="western">
            <surname>Clarke</surname>
            <given-names>WR</given-names>
          </name>
        </person-group>
        <article-title>A study of various normalization procedures for within day electromyographic data</article-title>
        <source>J Electromyogr Kinesiol</source>  
        <year>1994</year>  
        <volume>4</volume>  
        <issue>1</issue>  
        <fpage>47</fpage>  
        <lpage>59</lpage>  
        <pub-id pub-id-type="doi">10.1016/1050-6411(94)90026-4</pub-id>
        <pub-id pub-id-type="medline">20870546</pub-id>
        <pub-id pub-id-type="pii">1050-6411(94)90026-4</pub-id></nlm-citation>
      </ref>
      <ref id="ref26">
        <label>26</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Chowdhury</surname>
            <given-names>RH</given-names>
          </name>
          <name name-style="western">
            <surname>Reaz</surname>
            <given-names>MB</given-names>
          </name>
          <name name-style="western">
            <surname>Ali</surname>
            <given-names>MA</given-names>
          </name>
          <name name-style="western">
            <surname>Bakar</surname>
            <given-names>AA</given-names>
          </name>
          <name name-style="western">
            <surname>Chellappan</surname>
            <given-names>K</given-names>
          </name>
          <name name-style="western">
            <surname>Chang</surname>
            <given-names>TG</given-names>
          </name>
        </person-group>
        <article-title>Surface electromyography signal processing and classification techniques</article-title>
        <source>Sensors (Basel)</source>  
        <year>2013</year>  
        <month>09</month>  
        <day>17</day>  
        <volume>13</volume>  
        <issue>9</issue>  
        <fpage>12431</fpage>  
        <lpage>66</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://www.mdpi.com/resolver?pii=s130912431"/>
        </comment>  
        <pub-id pub-id-type="doi">10.3390/s130912431</pub-id>
        <pub-id pub-id-type="medline">24048337</pub-id>
        <pub-id pub-id-type="pii">s130912431</pub-id>
        <pub-id pub-id-type="pmcid">PMC3821366</pub-id></nlm-citation>
      </ref>
      <ref id="ref27">
        <label>27</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bland</surname>
            <given-names>JM</given-names>
          </name>
          <name name-style="western">
            <surname>Altman</surname>
            <given-names>DG</given-names>
          </name>
        </person-group>
        <article-title>Statistical methods for assessing agreement between two methods of clinical measurement</article-title>
        <source>Lancet</source>  
        <year>1986</year>  
        <month>02</month>  
        <day>8</day>  
        <volume>1</volume>  
        <issue>8476</issue>  
        <fpage>307</fpage>  
        <lpage>10</lpage>  
        <pub-id pub-id-type="medline">2868172</pub-id>
        <pub-id pub-id-type="pii">S0140-6736(86)90837-8</pub-id></nlm-citation>
      </ref>
      <ref id="ref28">
        <label>28</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Shrout</surname>
            <given-names>PE</given-names>
          </name>
          <name name-style="western">
            <surname>Fleiss</surname>
            <given-names>JL</given-names>
          </name>
        </person-group>
        <article-title>Intraclass correlations: uses in assessing rater reliability</article-title>
        <source>Psychol Bull</source>  
        <year>1979</year>  
        <month>03</month>  
        <volume>86</volume>  
        <issue>2</issue>  
        <fpage>420</fpage>  
        <lpage>8</lpage>  
        <pub-id pub-id-type="medline">18839484</pub-id></nlm-citation>
      </ref>
      <ref id="ref29">
        <label>29</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Watson</surname>
            <given-names>PF</given-names>
          </name>
          <name name-style="western">
            <surname>Petrie</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>Method agreement analysis: a review of correct methodology</article-title>
        <source>Theriogenology</source>  
        <year>2010</year>  
        <month>06</month>  
        <volume>73</volume>  
        <issue>9</issue>  
        <fpage>1167</fpage>  
        <lpage>79</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="https://linkinghub.elsevier.com/retrieve/pii/S0093-691X(10)00023-3"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1016/j.theriogenology.2010.01.003</pub-id>
        <pub-id pub-id-type="medline">20138353</pub-id>
        <pub-id pub-id-type="pii">S0093-691X(10)00023-3</pub-id></nlm-citation>
      </ref>
      <ref id="ref30">
        <label>30</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Barnhart</surname>
            <given-names>HX</given-names>
          </name>
          <name name-style="western">
            <surname>Haber</surname>
            <given-names>MJ</given-names>
          </name>
          <name name-style="western">
            <surname>Lin</surname>
            <given-names>LI</given-names>
          </name>
        </person-group>
        <article-title>An overview on assessing agreement with continuous measurements</article-title>
        <source>J Biopharm Stat</source>  
        <year>2007</year>  
        <volume>17</volume>  
        <issue>4</issue>  
        <fpage>529</fpage>  
        <lpage>69</lpage>  
        <pub-id pub-id-type="doi">10.1080/10543400701376480</pub-id>
        <pub-id pub-id-type="medline">17613641</pub-id>
        <pub-id pub-id-type="pii">780211394</pub-id></nlm-citation>
      </ref>
      <ref id="ref31">
        <label>31</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Cicchetti</surname>
            <given-names>DV</given-names>
          </name>
        </person-group>
        <article-title>Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology</article-title>
        <source>Psychol Assess</source>  
        <year>1994</year>  
        <volume>6</volume>  
        <issue>4</issue>  
        <fpage>284</fpage>  
        <lpage>90</lpage>  
        <pub-id pub-id-type="doi">10.1037/1040-3590.6.4.284</pub-id></nlm-citation>
      </ref>
      <ref id="ref32">
        <label>32</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Schmidt</surname>
            <given-names>B</given-names>
          </name>
        </person-group>
        <article-title>Proof of Principle studies</article-title>
        <source>Epilepsy Res</source>  
        <year>2006</year>  
        <month>01</month>  
        <volume>68</volume>  
        <issue>1</issue>  
        <fpage>48</fpage>  
        <lpage>52</lpage>  
        <pub-id pub-id-type="doi">10.1016/j.eplepsyres.2005.09.019</pub-id>
        <pub-id pub-id-type="medline">16377153</pub-id>
        <pub-id pub-id-type="pii">S0920-1211(05)00249-4</pub-id></nlm-citation>
      </ref>
      <ref id="ref33">
        <label>33</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Sarafino</surname>
            <given-names>EP</given-names>
          </name>
          <name name-style="western">
            <surname>Goehring</surname>
            <given-names>P</given-names>
          </name>
        </person-group>
        <article-title>Age comparisons in acquiring biofeedback control and success in reducing headache pain</article-title>
        <source>Ann Behav Med</source>  
        <year>2000</year>  
        <volume>22</volume>  
        <issue>1</issue>  
        <fpage>10</fpage>  
        <lpage>16</lpage>  
        <pub-id pub-id-type="medline">10892524</pub-id></nlm-citation>
      </ref>
      <ref id="ref34">
        <label>34</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bergmann</surname>
            <given-names>JH</given-names>
          </name>
          <name name-style="western">
            <surname>McGregor</surname>
            <given-names>AH</given-names>
          </name>
        </person-group>
        <article-title>Body-worn sensor design: what do patients and clinicians want?</article-title>
        <source>Ann Biomed Eng</source>  
        <year>2011</year>  
        <month>09</month>  
        <volume>39</volume>  
        <issue>9</issue>  
        <fpage>2299</fpage>  
        <lpage>312</lpage>  
        <pub-id pub-id-type="doi">10.1007/s10439-011-0339-9</pub-id>
        <pub-id pub-id-type="medline">21674260</pub-id></nlm-citation>
      </ref>
      <ref id="ref35">
        <label>35</label>
        <nlm-citation citation-type="book">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Fleiss</surname>
            <given-names>JL</given-names>
          </name>
        </person-group>
        <source>Design and Analysis of Clinical Experiments</source>  
        <year>2011</year>  
        <publisher-loc>Hoboken, NJ</publisher-loc>
        <publisher-name>John Wiley &#38; Sons</publisher-name></nlm-citation>
      </ref>
      <ref id="ref36">
        <label>36</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Walter</surname>
            <given-names>SD</given-names>
          </name>
          <name name-style="western">
            <surname>Eliasziw</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Donner</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>Sample size and optimal designs for reliability studies</article-title>
        <source>Stat Med</source>  
        <year>1998</year>  
        <month>01</month>  
        <day>15</day>  
        <volume>17</volume>  
        <issue>1</issue>  
        <fpage>101</fpage>  
        <lpage>10</lpage>  
        <pub-id pub-id-type="medline">9463853</pub-id>
        <pub-id pub-id-type="pii">10.1002/(SICI)1097-0258(19980115)17:1&#60;101::AID-SIM727&#62;3.0.CO;2-E</pub-id></nlm-citation>
      </ref>
      <ref id="ref37">
        <label>37</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Merletti</surname>
            <given-names>R</given-names>
          </name>
          <name name-style="western">
            <surname>di Torino</surname>
            <given-names>P</given-names>
          </name>
        </person-group>
        <article-title>Standards for reporting EMG data</article-title>
        <source>J. Electromyogr Kinesiol</source>  
        <year>1999</year>  
        <volume>9</volume>  
        <issue>1</issue>  
        <fpage>3</fpage>  
        <lpage>4</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://earc.eng.niigata-u.ac.jp/links/ISEK_Standards.pdf"/>
        </comment> </nlm-citation>
      </ref>
      <ref id="ref38">
        <label>38</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Kelechi</surname>
            <given-names>TJ</given-names>
          </name>
          <name name-style="western">
            <surname>Michel</surname>
            <given-names>Y</given-names>
          </name>
          <name name-style="western">
            <surname>Wiseman</surname>
            <given-names>J</given-names>
          </name>
        </person-group>
        <article-title>Are infrared and thermistor thermometers interchangeable for measuring localized skin temperature?</article-title>
        <source>J Nurs Meas</source>  
        <year>2006</year>  
        <volume>14</volume>  
        <issue>1</issue>  
        <fpage>19</fpage>  
        <lpage>30</lpage>  
        <pub-id pub-id-type="medline">16764175</pub-id></nlm-citation>
      </ref>
      <ref id="ref39">
        <label>39</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Ives</surname>
            <given-names>JC</given-names>
          </name>
          <name name-style="western">
            <surname>Wigglesworth</surname>
            <given-names>JK</given-names>
          </name>
        </person-group>
        <article-title>Sampling rate effects on surface EMG timing and amplitude measures</article-title>
        <source>Clin Biomech (Bristol, Avon)</source>  
        <year>2003</year>  
        <month>07</month>  
        <volume>18</volume>  
        <issue>6</issue>  
        <fpage>543</fpage>  
        <lpage>52</lpage>  
        <pub-id pub-id-type="medline">12828904</pub-id>
        <pub-id pub-id-type="pii">S0268003303000895</pub-id></nlm-citation>
      </ref>
      <ref id="ref40">
        <label>40</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Durkin</surname>
            <given-names>JL</given-names>
          </name>
          <name name-style="western">
            <surname>Callaghan</surname>
            <given-names>JP</given-names>
          </name>
        </person-group>
        <article-title>Effects of minimum sampling rate and signal reconstruction on surface electromyographic signals</article-title>
        <source>J Electromyogr Kinesiol</source>  
        <year>2005</year>  
        <month>10</month>  
        <volume>15</volume>  
        <issue>5</issue>  
        <fpage>474</fpage>  
        <lpage>81</lpage>  
        <pub-id pub-id-type="doi">10.1016/j.jelekin.2005.02.003</pub-id>
        <pub-id pub-id-type="medline">15935959</pub-id>
        <pub-id pub-id-type="pii">S1050-6411(05)00036-2</pub-id></nlm-citation>
      </ref>
      <ref id="ref41">
        <label>41</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>van Boxtel</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>Optimal signal bandwidth for the recording of surface EMG activity of facial, jaw, oral, and neck muscles</article-title>
        <source>Psychophysiol</source>  
        <year>2001</year>  
        <month>01</month>  
        <volume>38</volume>  
        <issue>1</issue>  
        <fpage>22</fpage>  
        <lpage>34</lpage>  
        <pub-id pub-id-type="medline">11321618</pub-id></nlm-citation>
      </ref>
      <ref id="ref42">
        <label>42</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>De Luca</surname>
            <given-names>CJ</given-names>
          </name>
          <name name-style="western">
            <surname>Gilmore</surname>
            <given-names>LD</given-names>
          </name>
          <name name-style="western">
            <surname>Kuznetsov</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Roy</surname>
            <given-names>SH</given-names>
          </name>
        </person-group>
        <article-title>Filtering the surface EMG signal: movement artifact and baseline noise contamination</article-title>
        <source>J Biomech</source>  
        <year>2010</year>  
        <month>05</month>  
        <day>28</day>  
        <volume>43</volume>  
        <issue>8</issue>  
        <fpage>1573</fpage>  
        <lpage>9</lpage>  
        <pub-id pub-id-type="doi">10.1016/j.jbiomech.2010.01.027</pub-id>
        <pub-id pub-id-type="medline">20206934</pub-id>
        <pub-id pub-id-type="pii">S0021-9290(10)00063-1</pub-id></nlm-citation>
      </ref>
      <ref id="ref43">
        <label>43</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Müller</surname>
            <given-names>R</given-names>
          </name>
          <name name-style="western">
            <surname>Büttner</surname>
            <given-names>P</given-names>
          </name>
        </person-group>
        <article-title>A critical discussion of intraclass correlation coefficients</article-title>
        <source>Stat Med</source>  
        <year>1994</year>  
        <volume>13</volume>  
        <issue>23-24</issue>  
        <fpage>2465</fpage>  
        <lpage>76</lpage>  
        <pub-id pub-id-type="medline">7701147</pub-id></nlm-citation>
      </ref>
      <ref id="ref44">
        <label>44</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>McGraw</surname>
            <given-names>KO</given-names>
          </name>
          <name name-style="western">
            <surname>Wong</surname>
            <given-names>SP</given-names>
          </name>
        </person-group>
        <article-title>Forming inferences about some intraclass correlation coefficients</article-title>
        <source>Psychol Methods</source>  
        <year>1996</year>  
        <volume>1</volume>  
        <issue>1</issue>  
        <fpage>30</fpage>  
        <lpage>46</lpage>  
        <pub-id pub-id-type="doi">10.1037/1082-989X.1.1.30</pub-id></nlm-citation>
      </ref>
      <ref id="ref45">
        <label>45</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bartko</surname>
            <given-names>JJ</given-names>
          </name>
        </person-group>
        <article-title>The intraclass correlation coefficient as a measure of reliability</article-title>
        <source>Psychol Rep</source>  
        <year>1966</year>  
        <month>08</month>  
        <volume>19</volume>  
        <issue>1</issue>  
        <fpage>3</fpage>  
        <lpage>11</lpage>  
        <pub-id pub-id-type="doi">10.2466/pr0.1966.19.1.3</pub-id>
        <pub-id pub-id-type="medline">5942109</pub-id></nlm-citation>
      </ref>
      <ref id="ref46">
        <label>46</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bland</surname>
            <given-names>JM</given-names>
          </name>
          <name name-style="western">
            <surname>Altman</surname>
            <given-names>DG</given-names>
          </name>
        </person-group>
        <article-title>Measuring agreement in method comparison studies</article-title>
        <source>Stat Methods Med Res</source>  
        <year>1999</year>  
        <month>06</month>  
        <volume>8</volume>  
        <issue>2</issue>  
        <fpage>135</fpage>  
        <lpage>60</lpage>  
        <pub-id pub-id-type="medline">10501650</pub-id></nlm-citation>
      </ref>
      <ref id="ref47">
        <label>47</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bland</surname>
            <given-names>JM</given-names>
          </name>
          <name name-style="western">
            <surname>Altman</surname>
            <given-names>DG</given-names>
          </name>
        </person-group>
        <article-title>A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement</article-title>
        <source>Comput Biol Med</source>  
        <year>1990</year>  
        <volume>20</volume>  
        <issue>5</issue>  
        <fpage>337</fpage>  
        <lpage>40</lpage>  
        <pub-id pub-id-type="medline">2257734</pub-id></nlm-citation>
      </ref>
      <ref id="ref48">
        <label>48</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Clancy</surname>
            <given-names>EA</given-names>
          </name>
          <name name-style="western">
            <surname>Farry</surname>
            <given-names>KA</given-names>
          </name>
        </person-group>
        <article-title>Adaptive whitening of the electromyogram to improve amplitude estimation</article-title>
        <source>IEEE Trans Biomed Eng</source>  
        <year>2000</year>  
        <month>06</month>  
        <volume>47</volume>  
        <issue>6</issue>  
        <fpage>709</fpage>  
        <lpage>19</lpage>  
        <pub-id pub-id-type="doi">10.1109/10.844217</pub-id>
        <pub-id pub-id-type="medline">10833845</pub-id></nlm-citation>
      </ref>
      <ref id="ref49">
        <label>49</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Rausa</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Palomba</surname>
            <given-names>D</given-names>
          </name>
          <name name-style="western">
            <surname>Cevoli</surname>
            <given-names>S</given-names>
          </name>
          <name name-style="western">
            <surname>Lazzerini</surname>
            <given-names>L</given-names>
          </name>
          <name name-style="western">
            <surname>Sancisi</surname>
            <given-names>E</given-names>
          </name>
          <name name-style="western">
            <surname>Cortelli</surname>
            <given-names>P</given-names>
          </name>
          <name name-style="western">
            <surname>Pierangeli</surname>
            <given-names>G</given-names>
          </name>
        </person-group>
        <article-title>Biofeedback in the prophylactic treatment of medication overuse headache: a pilot randomized controlled trial</article-title>
        <source>J Headache Pain</source>  
        <year>2016</year>  
        <month>12</month>  
        <volume>17</volume>  
        <issue>1</issue>  
        <fpage>87</fpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="https://link.springer.com/article/10.1186/s10194-016-0679-9"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1186/s10194-016-0679-9</pub-id>
        <pub-id pub-id-type="medline">27655371</pub-id>
        <pub-id pub-id-type="pii">10.1186/s10194-016-0679-9</pub-id>
        <pub-id pub-id-type="pmcid">PMC5031562</pub-id></nlm-citation>
      </ref>
      <ref id="ref50">
        <label>50</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Rains</surname>
            <given-names>JC</given-names>
          </name>
        </person-group>
        <article-title>Change mechanisms in EMG biofeedback training: cognitive changes underlying improvements in tension headache</article-title>
        <source>Headache</source>  
        <year>2008</year>  
        <month>05</month>  
        <volume>48</volume>  
        <issue>5</issue>  
        <fpage>735</fpage>  
        <lpage>6; discussion 736</lpage>  
        <pub-id pub-id-type="doi">10.1111/j.1526-4610.2008.01119_1.x</pub-id>
        <pub-id pub-id-type="medline">18471128</pub-id>
        <pub-id pub-id-type="pii">HED1119_1</pub-id></nlm-citation>
      </ref>
      <ref id="ref51">
        <label>51</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Munster-Segev</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Fuerst</surname>
            <given-names>O</given-names>
          </name>
          <name name-style="western">
            <surname>Kaplan</surname>
            <given-names>SA</given-names>
          </name>
          <name name-style="western">
            <surname>Chan</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>Incorporation of a stress reducing mobile app in the care of patients with type 2 diabetes: a prospective study</article-title>
        <source>JMIR mHealth and uHealth</source>  
        <year>2017</year>  
        <volume>5</volume>  
        <issue>5</issue>  
        <fpage>e75</fpage>  
        <pub-id pub-id-type="medline">28554881</pub-id></nlm-citation>
      </ref>
      <ref id="ref52">
        <label>52</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Uddin</surname>
            <given-names>AA</given-names>
          </name>
          <name name-style="western">
            <surname>Morita</surname>
            <given-names>PP</given-names>
          </name>
          <name name-style="western">
            <surname>Tallevi</surname>
            <given-names>K</given-names>
          </name>
          <name name-style="western">
            <surname>Armour</surname>
            <given-names>K</given-names>
          </name>
          <name name-style="western">
            <surname>Li</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Nolan</surname>
            <given-names>RP</given-names>
          </name>
          <name name-style="western">
            <surname>Cafazzo</surname>
            <given-names>JA</given-names>
          </name>
        </person-group>
        <article-title>Development of a wearable cardiac monitoring system for behavioral neurocardiac training: a usability study</article-title>
        <source>JMIR Mhealth Uhealth</source>  
        <year>2016</year>  
        <volume>4</volume>  
        <issue>2</issue>  
        <fpage>e45</fpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:type="simple" xlink:href="http://mhealth.jmir.org/2016/2/e45/"/>
        </comment>  
        <pub-id pub-id-type="doi">10.2196/mhealth.5288</pub-id>
        <pub-id pub-id-type="medline">27106171</pub-id>
        <pub-id pub-id-type="pii">v4i2e45</pub-id>
        <pub-id pub-id-type="pmcid">PMC4859872</pub-id></nlm-citation>
      </ref>
      <ref id="ref53">
        <label>53</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Dooley</surname>
            <given-names>EE</given-names>
          </name>
          <name name-style="western">
            <surname>Golaszewski</surname>
            <given-names>NM</given-names>
          </name>
          <name name-style="western">
            <surname>Bartholomew</surname>
            <given-names>JB</given-names>
          </name>
        </person-group>
        <article-title>Estimating accuracy at exercise intensities: a comparative study of self-monitoring heart rate and physical activity wearable devices</article-title>
        <source>JMIR mHealth and uHealth</source>  
        <year>2017</year>  
        <volume>5</volume>  
        <issue>3</issue>  
        <fpage>e34</fpage>  
        <pub-id pub-id-type="medline">28302596</pub-id></nlm-citation>
      </ref>
    </ref-list>
  </back>
</article>
